Rapid Visual Screening of Buildings for Potential Seismic Hazards: Supporting Documentation

Rapid Visual Screening of Buildings for Potential Seismic Hazards: Supporting Documentation PDF

Author:

Publisher: Government Printing Office

Published: 2015

Total Pages: 206

ISBN-13: 9780160926754

DOWNLOAD EBOOK →

The Rapid Visual Screening (RVS) handbook can be used by trained personnel to identify, inventory, and screen buildings that are potentially seismically vulnerable. The RVS procedure comprises a method and several forms that help users to quickly identify, inventory, and score buildings according to their risk of collapse if hit by major earthquakes. The RVS handbook describes how to identify the structural type and key weakness characteristics, how to complete the screening forms, and how to manage a successful RVS program.

Rapid Visual Screening of Buildings for Potential Seismic Hazards: A Handbook

Rapid Visual Screening of Buildings for Potential Seismic Hazards: A Handbook PDF

Author: Federal Emergency Agency

Publisher: FEMA

Published: 2013-04-03

Total Pages: 164

ISBN-13:

DOWNLOAD EBOOK →

This FEMA 154 Report, Rapid Visual Screening of Buildings for Potential Seismic Hazards: A Handbook, is the first of a two-volume publication on a recommended methodology for rapid visual screening of buildings for potential seismic hazards. The technical basis for the methodology, including the scoring system and its development, are contained in the companion FEMA 155 report, Rapid Visual Screening of Buildings for Potential Seismic Hazards: Supporting Documentation. The rapid visual screening procedure (RVS) has been developed for a broad audience, including building officials and inspectors, and government agency and private-sector building owners, to identify, inventory, and rank buildings that are potentially seismically hazardous. Although RVS is applicable to all buildings, its principal purpose is to identify (1) older buildings designed and constructed before the adoption of adequate seismic design and detailing requirements, (2) buildings on soft or poor soils, or (3) buildings having performance characteristics that negatively influence their seismic response. Once identified as potentially hazardous, such buildings should be further evaluated by a design professional experienced in seismic design to determine if, in fact, they are seismically hazardous. The RVS uses a methodology based on a "sidewalk survey" of a building and a Data Collection Form, which the person conducting the survey (hereafter referred to as the screener) completes, based on visual observation of the building from the exterior, and if possible, the interior. The Data Collection Form includes space for documenting building identification information, including its use and size, a photograph of the building, sketches, and documentation of pertinent data related to seismic performance, including the development of a numeric seismic hazard score. Once the decision to conduct rapid visual screening for a community or group of buildings has been made by the RVS authority, the screening effort can be expedited by pre-planning, including the training of screeners, and careful overall management of the process. Completion of the Data Collection Form in the field begins with identifying the primary structural lateral-load-resisting system and structural materials of the building. Basic Structural Hazard Scores for various building types are provided on the form, and the screener circles the appropriate one. For many buildings, viewed only from the exterior, this important decision requires the screener to be trained and experienced in building construction. The procedure presented in this Handbook is meant to be the preliminary screening phase of a multi-phase procedure for identifying potentially hazardous buildings. Buildings identified by this procedure must be analyzed in more detail by an experienced seismic design professional. Because rapid visual screening is designed to be performed from the street, with interior inspection not always possible, hazardous details will not always be visible, and seismically hazardous buildings may not be identified as such. Conversely, buildings initially identified as potentially hazardous by RVS may prove to be adequate.